Optimization of Solar Transmittance of a Three-Layer Glass Structure Based on the Ant Colony Algorithm

Authors

  • Bowen Deng

DOI:

https://doi.org/10.61173/j2trzt64

Keywords:

Ant Colony Algorithm, Triple-pane glass, Solar transmittance, Optimization

Abstract

Currently, high temperatures occur frequently in summer, and the overall duration of summer has been prolonged. Glass that reduces sunlight transmittance is an economical and effective passive energy-saving measure to lower indoor energy consumption. The structural parameters and types of glass have a significant impact on their solar transmittance. In this study, the optimization of the solar transmittance of three layers of ordinary glass by the thickness of the glass was carried out. The radiant energy of sunlight passing through Windows mainly exists in the near-infrared band, while ultraviolet radiation is harmful to the human body. Therefore, under the premise of ensuring lighting, minimizing the transmittance of the near-infrared and ultraviolet bands as much as possible can effectively reduce solar radiation and thereby lower energy consumption. The research achieves multi-objective optimization by establishing a spectral transmission model ranging from 300 to 2000nm and combining the ant colony algorithm to minimize the near-infrared and ultraviolet bands while ensuring daylighting. The research results show that when the thickness of the three-layer glass is 5.103mm, 5.724mm, and 5.310mm, it can minimize solar radiation energy to the greatest extent and ensure lighting. In this case, the total solar radiation transmission energy of the three-layer glass decreased from 1267.81 W/m2 before optimization to 997.37 W/m2, a reduction of 21.33%.

References

[1] Jiang H., Wu H., Cao Y. Evaluation of Energy-Saving Schemes for Residential Windows Based on TOPSIS Method. Sichuan Architectural Science Research, 2014, 40(03), 317–319.

[2] Jin Y., Li H., Xiong Y., et al. Research on Energy Conservation of South-Facing Windows in Residential Buildings from a Three-Dimensional Spatial Perspective in Hot Summer and Cold Winter Areas. Building Energy Conservation, 2017, 45(10),102–106.

[3] Fu J. Research on Building Thermal Management Based on Hydrogel Composite Glass. Wuhan University, 2022.

[4] Ma Y. Parameter Optimization and Performance Research of Thermal Insulation Phase Change Multilayer Glass Windows. Northeast Petroleum University, 2023.

[5] Qi S., Zeng H., Yu H., et al. Evaluation of Energy-Saving Performance of Photochromic Glass in Buildings. Bulletin of Silicate, 2022, 41(04),1177–1184+1194.

[6] Zheng Y., Xie J., Ma S., et al. Research on Daylighting and Energy-Saving Optimization Design of Low-Emissivity (Low-E) Glass in Public Building Renovation. Residential Industry, 2025, (08),29–32.

[7] Mi W., Pu J., Shen C., et al. Vacuum-Structured Electrochromic Glazing Windows with Ultra-Low U-Values for Building Energy Savings in All Climatic Zones. Energy, 2025, 336,138496–138496.

[8] Wang Q., Wu H., Bai S., et al. Towards Net Zero Energy Buildings: Thermal and Energy Performance of CdTe PV Glazing in Tropical Island Regions. Energy & Buildings, 2025, 347(PA),116271–116271.

[9] Xia X., Zhou Y. Theoretical Research Progress of Ant Colony Optimization Algorithm. Journal of Intelligent Systems, 2016, 11(01),27–36.

[10] Hu X., Ding Q., Li Y. Review of Ant Colony Algorithm Research. Journal of Management Engineering, 2008, (02),74– 79.

Downloads

Published

2026-02-28